Atmosphere \\ Ventures, Inc.
Atmosphere Ventures · Certified Water Quality
Atmosphere Ventures, Inc.
WaterPROOF™
Independent Certified Results

Water you can trust — WaterPROOF™.

WaterPROOF™ · independent, third-party laboratory analysis of Origen Wellspring water (Therma-Stor filtration module) · EPA reference methods.

Arsenic, lead, mercury, aluminum — and all 60 regulated volatile organics: NON-DETECT. The trip blank too.
0
analytes above EPA MCL
92
analytes tested (32 metals · 60 VOCs)
ND
arsenic · lead · mercury
60 / 60
volatile organics non-detect

Regulated Metals & Inorganics — EPA 200.8 / 180.1

AnalyteResultEPA MCLStatus
ArsenicND10 µg/L✓
LeadND15 µg/L✓
MercuryND2 µg/L✓
CadmiumND5 µg/L✓
ChromiumND100 µg/L✓
AntimonyND6 µg/L✓
BerylliumND4 µg/L✓
SeleniumND50 µg/L✓
ThalliumND2 µg/L✓
UraniumND30 µg/L✓
NickelND100 µg/L✓
CopperND1300 µg/L✓
SilverND100 µg/L✓
CobaltND—✓
AluminumND0.2 mg/L✓
IronND0.3 mg/L†✓
TurbidityND1 NTU✓
Barium53 µg/L2000 µg/L✓ trace
Manganese1.3 µg/LJ50 µg/L✓ trace
Zinc4.1 µg/LJ5000 µg/L✓ trace
Calcium9.0 mg/Lmineral✓
Magnesium5.5 mg/Lmineral✓
Potassium1.6 mg/Lmineral✓
Sodium0.35 mg/LJ—✓
Hardness45 mg/L—soft

Also non-detect: molybdenum, tin, vanadium, boron 23 µg/L (no MCL), silicon 83 µg/L, strontium 7.5 µg/L, titanium 1.2 µg/LJ. J = detected between detection & quantitation limits (trace). Metals run as EPA 200.8 semi-quantitative screening scan.

By design — not contamination. The only constituents present above trace are beneficial minerals put back on purpose. Origen condenses and purifies atmospheric water to near-zero dissolved solids, then a Pentair Calcite remineralization stage reintroduces calcium and magnesium (hardness ≈ 45 mg/L, TDS 60–70) to restore clean taste, balance pH to 7.5–8.5, and return healthful minerals. Every regulated contaminant — heavy metals and all 60 VOCs — remains Non-Detect. What you see detected, we intended.

Volatile Organic Compounds — EPA 524.2 (60 analytes) · ALL NON-DETECT

Benzene (MCL 5)Vinyl chloride (0.2)Trichloroethene/TCE (5)Tetrachloroethene/PCE (5)Carbon tetrachloride (5)1,2-Dichloroethane (5)1,1-Dichloroethene (7)cis-1,2-Dichloroethene (70)trans-1,2-Dichloroethene (100)Dichloromethane (5)1,2-Dichloropropane (5)Toluene (1000)Ethylbenzene (700)Xylenes, total (10000)Styrene (100)Chlorobenzene (100)1,2-Dichlorobenzene (600)1,4-Dichlorobenzene (75)1,2,4-Trichlorobenzene (70)1,1,1-Trichloroethane (200)1,1,2-Trichloroethane (5)Chloroform (80)Bromodichloromethane (80)Dibromochloromethane (80)Bromoform (80)1,2-Dibromoethane/EDB (0.05)DBCP (—)MTBE+ 32 more VOCs

Insist on proof.

The gold standard isn't a claim — it's WaterPROOF™: an independent, third-party certified lab report, every regulated contaminant measured against EPA Maximum Contaminant Levels. Before you trust any water source with your people and your mission, ask your current AWG provider to put the same on the table — independent, certified, analyte-by-analyte results. We're confident in what you'll find — and in what you won't.

Don't take our word for it — read the report. No form, no email, no gate. The full certified analysis, exactly as the laboratory issued it: Origen Wellspring AWG100 — Water Quality Test Report, 17 Mar 2026 (PDF, 7 pp.)  ·  Northern Lake Service, Inc. · Work Order CE02094

Then hold us to it. Once you've read that report, you know what we do with a number: we publish it whether or not it flatters us — the trip blank, the detection limits, the constituents that are present and why. Everything else we tell you is built the same way — the output at your site, the delivery date, the invoice. Talk to us at that same standard. Tell us where the water has to work, and what happens if it doesn't. Start the conversation →

Provenance. Laboratory: Northern Lake Service, Inc. — Pure Water Labs (Lodi / Crandon, WI) · WDNR Certified Lab ID 721026460. Work Order CE02094. Sample "ThermaStor Filter" (CE02094-03), collected 03/02/2026, reported 03/17/2026. Methods: EPA 200.8 (metals), EPA 524.2 Rev 4.1 (volatile organics), EPA 180.1 (turbidity). A companion trip-blank (CE02094-04) returned all-non-detect, confirming sampling & transport integrity; VOC surrogate recoveries within control limits. Results apply to the sample(s) analyzed per chain of custody. Full certified report available on request. ND = not detected at or above the method detection limit. MCL = EPA Maximum Contaminant Level (†secondary standard). Metals reported as a semi-quantitative screening scan.
/.|||\°/   atmosphere.ventures  ·  Water You Can Trust™